• -20%
Fire Alarm 2 Zone Control Panel
search
  • Fire Alarm 2 Zone Control Panel

Fire Alarm 2 Zone Control Panel

₹8,438
₹6,750 Save 20%
No tax

2 Zone LCD Control panel

Quantity

 

Security policy

 

Delivery policy

 

Return policy

The Ravel Fire Alarm 2 Zone Control Panel is a critical part of fire safety systems that provides comprehensive monitoring and control for small to medium-sized environments. It is designed to efficiently handle fire detection and alerting needs, making it an ideal choice for facilities such as small offices, shops, warehouses, and other similar establishments. In this article, we'll delve into the features, functionality, and benefits of the Ravel Fire Alarm 2 Zone Control Panel, as well as provide some insights into installation and maintenance.

Features and Functionality

1. Two-Zone Configuration: The Ravel Fire Alarm Control Panel is designed to support up to two detection zones. Each zone can accommodate a variety of fire detection devices, such as smoke detectors, heat detectors, and manual call points, providing flexibility and adaptability to the specific needs of your premises.

2. LED Indicators: The control panel features a set of LED indicators that provide visual notifications of system status, such as power, fire alarm, fault, and zone activity. These indicators make it easy to quickly assess the system's status at a glance.

3. Audible and Visual Alarms: The panel supports external alarm devices, including sirens and strobe lights, to alert occupants in the event of a fire. The panel also features built-in sounders for internal audible notifications.

4. Reset and Silence Functions: The panel includes dedicated buttons for silencing alarms and resetting the system once the fire incident is managed. These functions provide convenient control for authorized personnel.

5. Battery Backup: To ensure continuous operation during power outages, the Ravel Fire Alarm Control Panel supports battery backup, allowing the system to remain functional and responsive even without main power.

6. Fire and Fault Relays: The control panel includes fire and fault relays, which can be used to trigger additional equipment such as elevators, HVAC systems, or automatic doors. This integration helps enhance overall building safety during a fire emergency.

7. Easy Installation and Maintenance: The Ravel Fire Alarm 2 Zone Control Panel is designed with user-friendly installation in mind. Its straightforward wiring and configuration make setup a breeze for professionals. Additionally, the panel is built for ease of maintenance, minimizing downtime during routine checks.

Benefits

  • Reliable Fire Detection: By supporting a range of detectors and call points, the Ravel Fire Alarm 2 Zone Control Panel ensures that fires are detected promptly and accurately.

  • Customizable Alerting: The panel's support for various audible and visual alarms, as well as integration with other safety systems, allows for a comprehensive alerting strategy tailored to your facility.

  • User-Friendly Interface: The control panel's intuitive design, including LED indicators and dedicated control buttons, simplifies operation for authorized personnel.

  • Safety Compliance: Using a certified fire alarm control panel like Ravel's ensures compliance with local safety regulations and codes, providing peace of mind for building owners and occupants.

Installation and Maintenance

Installation

1. Planning: Begin with a detailed assessment of the building's layout and fire safety requirements. Identify the locations where fire detection devices will be placed and plan the wiring routes.

2. Mounting: Mount the control panel at a central, easily accessible location within the facility. Ensure that the panel is installed according to the manufacturer's guidelines and local regulations.

3. Wiring: Connect the fire detection devices to the appropriate zones on the control panel. Follow the wiring diagram provided in the panel's user manual for proper installation.

4. Testing: Once the installation is complete, conduct a thorough system test to ensure all detectors, alarms, and relays are functioning correctly.

5. Documentation: Keep detailed records of the installation process, including wiring diagrams and device locations, for future reference.

Maintenance

1. Routine Inspections: Perform regular visual inspections of the control panel and connected devices to check for signs of damage or wear.

2. Functional Testing: Conduct periodic functional tests of the control panel and fire detection devices to verify their performance. This may involve activating detectors or manual call points and ensuring the alarms and notifications are triggered.

3. Battery Check: Check the control panel's battery backup regularly and replace it as needed to maintain system reliability during power outages.

4. Software Updates: If the control panel supports software updates, ensure that it is running the latest firmware for optimal performance and security.

5. Record Maintenance: Maintain detailed logs of all inspections, tests, and maintenance activities. These records may be required for compliance audits and future troubleshooting.

Ravel